Level Inputs

Level Inputs interpret analog sources or other modules that have a range of output, created in Connections > Inputs, Outputs, and Modules.

Display prerequisite

This section appears after at least one included input source is configured in Configure > Connections > Inputs, Outputs, and Modules.

UI path

  1. Add an analog or similar source in Configuration > Connections > Inputs, Outputs, and Modules.
  2. Open Configuration > Definitions.
  3. Expand Level Inputs.
  4. Click Add Level Input Control.
  5. Select the input source.
  6. Choose Range, Center, or Map mode.
  7. Use fields and Learn controls to capture current hardware readings as you mark each location/reading.
  8. Use named values in Behaviors.

Modes

ModeUse it for
RangeNamed value bands such as low, safe, high, or station_3
CenterTarget values with tolerance around each target
MapContinuous output mapping to lighting, DMX, or another target